•PROJECTOR ON/STANDBY INDICATOR (1st byte)
Shows the status of the PROJECTOR ON/STANDBY POWER switch.
The parameter and the status of the PROJECTOR ON/STANDBY POWER switch are as shown in the following table.
PROJECTOR ON/STANDBY INDICATOR
STANDBY (The switch lights up red.) | 0x30 (‘0’) |
ON (The switch lights up red.) | 0x31 (‘1’) |
Cool off before entering STANDBY (the switch flashes green.) | 0x32 (‘2’) |
Example
When the projector is cooling off before entering standby (the switch flashes green) 0x41 0x32 0x0D
(‘A 2 CR’)
2.1.16 SCENE RECALL : 0x43 0x52 0x43 0x4C (‘CRCL’)
This command is used to recall a scene.
Note
This command can be used only when the SYSTEM TYPE selector on the
Packet format
0x43 0x52 0x43 0x4C “parameter” 0x0D
♦Parameter
The parameter consists of 1 byte of data.
Byte | Parameter |
1st | SCENE RECALL REQUEST |
•SCENE RECALL REQUEST (1st byte)
Specify the scene number to be recalled.
SCENE RECALL REQUEST |
|
1 | 0x31 (‘1’) |
2 | 0x32 (‘2’) |
3 | 0x33 (‘3’) |
4 | 0x34 (‘4’) |
5 | 0x35 (‘5’) |
6 | 0x36 (‘6’) |
7 | 0x37 (‘7’) |
8 | 0x38 (‘8’) |
Example
To recall scene No,7:
0x43 0x52 0x43 0x4C 0x37 0x0D (‘C R C L 7 CR’)
Page 18/43