Sony SRP-X500P manual Remote 1-6 Level 0x43 0x4C 0x56 0x4C ‘CLVL’, Channel 1st byte

Models: SRP-X500P

1 43
Download 43 pages 60.38 Kb
Page 10
Image 10

SRP-X500P RS-232C Interface Manual

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK (0x41 (‘A’)) in the order shown below.

0x41 parameter” 0x0D

The parameter consists of 8 bytes of data and is the same as that of the OUTPUT FADER command.

2.1.7 REMOTE 1-6 LEVEL : 0x43 0x4C 0x56 0x4C (‘CLVL’)

This command is used to set the level of the REMOTE faders.

The level of the REMOTE faders are reset to 0 dB when the SRP-X500P is turned off.

Packet format

0x43 0x4C 0x56 0x4C parameter” 0x0D

Parameter

The parameter consists of 2 bytes of data in the order shown in the following table.

Byte Parameter

1st Channel

2nd LEVEL

Channel (1st byte)

Specifies the REMOTE fader channel.

The parameter and the REMOTE fader channel are as shown in the following table.

Channel

REMOTE 1

0x42

(‘B’)

REMOTE 2

0x43

(‘C’)

REMOTE 3

0x44

(‘D’)

REMOTE 4

0x45

(‘E’)

REMOTE 5

0x46

(‘F’)

REMOTE 6

0x47

(‘G’)

Page 10/43