Sony SRP-X500P manual Scene Recall Parameter Request 0x52 0x52 0x43 0x4C ‘RRCL’, Scene No st byte

Models: SRP-X500P

1 43
Download 43 pages 60.38 Kb
Page 19
Image 19

SRP-X500P RS-232C Interface Manual

2.1.17SCENE RECALL PARAMETER REQUEST : 0x52 0x52 0x43 0x4C (‘RRCL’)

This command is used to read the recalled scene number from the SRP-X500P.

Packet format

0x52 0x52 0x43 0x4C 0x0D

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK (0x41(‘A’)) in the order shown below.

0x41 parameter” 0x0D

Parameter

The parameter consists of 1 byte of data.

Byte

Parameter

1st

SCENE No.

SCENE No. (1st byte)

Shows the recalled scene number, as shown in the following table.

SCENE No.

None

0x30 (‘0’)

1

0x31 (‘1’)

2

0x32 (‘2’)

3

0x33 (‘3’)

4

0x34 (‘4’)

5

0x35 (‘5’)

6

0x36 (‘6’)

7

0x37 (‘7’)

8

0x38 (‘8’)

Example

When no scene has been recalled: 0x41 0x30 0x0D

(‘A 0 CR’)