Sony SRP-X500P manual IR Output Mode Indicator 59th byte, Level Meter 60th-75th byte

Models: SRP-X500P

1 43
Download 43 pages 60.38 Kb
Page 33
Image 33

SRP-X500P RS-232C Interface Manual

IR OUTPUT MODE INDICATOR (59th byte)

Shows the status of the IR OUTPUT MODE button on the front panel of the SRP-X500P.

The correspondence of the parameter with the IR OUTPUT MODE button status is shown in the following table.

IR OUTPUT MODE

Normal operation (The button is turned off.)

0x30 (‘0’)

Transmission wait status (The button lights up.)

0x31 (‘1’)

Transmission in progress (The button flashes.)

0x32 (‘2’)

LEVEL METER (60th-75th byte)

Shows the level meter indication of the input/output channels.

The configuration of the parameter and the correspondence of the parameter with the level meters are the same as those of the LEVEL METER PARAMETER REQUEST command (page 21).

PROTECTION (76th byte)

Shows the protection circuit status of the power amplifiers in 8 bits of data.

MSB

 

 

 

 

 

 

LSB

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

0

1

0

CH3/4

CH3/4

CH1/2

CH1/2

DC

 

 

 

TEMP.

IC

TEMP.

IC

DETECTION

TEMP.

The bit for the power amplifier is 0 when the protection circuit is not activated and 1 when the protection circuit is activated due to increased internal temperature of the SRP-X500P.

IC

The bit for the power amplifier is 0 when the protection circuit incorporated in the IC is not activated and 1 when the protection circuit incorporated in the IC is activated.

DC DETECTION

When the protection circuit is not activated, The bit for the power amplifier is 0. When the DC power voltage is output to the SPEAKER CH terminals and the protection circuit is activated, the bit for the power amplifier is 1.

CLIP INDICATOR (77th byte)

Shows the CLIP indicator status in 8 bits of data.

The parameter shown for this command is the status of the CLIP indicators in the BLOCK screen and the OVER VIEW screen of the SRP-X500P Manager.

When the CLIP indicator is turned off, the corresponding bit is 0. When the CLIP indicator is turned on, the corresponding bit is 1.

MSB

 

 

 

 

 

 

LSB

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

0

1

0

0

CH 4

CH 3

CH 2

CH 1

Page 33/43

Page 33
Image 33
Sony SRP-X500P manual IR Output Mode Indicator 59th byte, Level Meter 60th-75th byte, Protection 76th byte