SRP-X500P RS-232C Interface Manual

FADER (1st-6th byte)

The level for each fader can be specified (in dB units).

The parameter and levels are as shown in the following table.

Level

 

Level

 

 

Level

 

 

-

0x30 (‘0’)

-20.0

0x40

(‘@’)

-4.5

0x50

(‘P’)

-70.0

0x31 (‘1’)

-19.0

0x41

(‘A’)

-4.0

0x51

(‘Q’)

-60.0

0x32 (‘2’)

-18.0

0x42

(‘B’)

-3.5

0x52

(‘R’)

-55.0

0x33 (‘3’)

-17.0

0x43

(‘C’)

-3.0

0x53

(‘S’)

-50.0

0x34 (‘4’)

-16.0

0x44

(‘D’)

-2.5

0x54

(‘T’)

-45.0

0x35 (‘5’)

-15.0

0x45

(‘E’)

-2.0

0x55

(‘U’)

-40.0

0x36 (‘6’)

-14.0

0x46

(‘F’)

-1.5

0x56

(‘V’)

-35.0

0x37 (‘7’)

-13.0

0x47

(‘G’)

-1.0

0x57

(‘W’)

-32.5

0x38 (‘8’)

-12.0

0x48

(‘H’)

-0.5

0x58

(‘X’)

-30.0

0x39 (‘9’)

-11.0

0x49

(‘I’)

0

0x59

(‘Y’)

-27.5

0x3A (‘:’)

-10.0

0x4A (‘J’)

+0.5

0x5A (‘Z’)

-25.0

0x3B (‘;’)

-9.0

0x4B (‘K’)

+1.0

0x5B (‘[‘)

-24.0

0x3C (‘<‘)

-8.0

0x4C (‘L’)

+1.5

0x5C (‘\’)

-23.0

0x3D (‘=‘)

-7.0

0x4D (‘M’)

+2.0

0x5D (‘]’)

-22.0

0x3E (‘>‘)

-6.0

0x4E (‘N’)

+2.5

0x5E (‘^’)

-21.0

0x3F (‘?’)

-5.0

0x4F (‘O’)

+3.0

0x5F (‘_’)

Level

 

 

+3.5

0x60

(‘`’)

+4.0

0x61

(‘a’)

+4.5

0x62

(‘b’)

+5.0

0x63

(‘c’)

+5.5

0x64

(‘d’)

+6.0

0x65

(‘e’)

+6.5

0x66

(‘f’)

+7.0

0x67

(‘g’)

+7.5

0x68

(‘h’)

+8.0

0x69

(‘i’)

+8.5

0x6A (‘j’)

+9.0

0x6B (‘k’)

+10.0

0x6C (‘l’)

Example

To set the level for each input fader as follows:

MIC 1/WL 1 INPUT : -10dB

MIC 2/WL 2 INPUT : -10dB

MIC 3 INPUT

: -10dB

MIC 4 INPUT

: -10dB

LINE INPUT

: 0dB

AV/RGB INPUT

: 0dB

0x43 0x50 0x4D 0x35 0x4A 0x4A 0x4A 0x4A 0x59 0x59 0x0D (‘C P M 5 J J J J Y Y CR’)

2.1.4 INPUT FADER REQUEST : 0x52 0x50 0x4D 0x35 (‘RPM5’)

This command is used to read the input fader settings from the SRP-X500P.

Packet format

0x52 0x50 0x4D 0x35 0x0D

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK (0x41 (‘A’)) in the order shown below.

0x41 parameter” 0x0D

The parameter consists of 6 bytes of data which are the same as those of the parameter of the INPUT FADER command.

Page 8/43

Page 8
Image 8
Sony SRP-X500P manual Input Fader Request 0x52 0x50 0x4D 0x35 ‘RPM5’, Fader 1st-6th byte