Manuals
/
Brands
/
Musical Instruments & Equipment
/
Music Mixer
/
Sony
/
Musical Instruments & Equipment
/
Music Mixer
Sony
SRP-X500P manual
1
1
43
43
Download
43 pages, 572.38 Kb
SRP-X500P RS-232C Interface Manual
Digital Powered Mixer
SRP-X500P
RS-232C Interface Manual
1st Edition
©
©
2
2
0
0
0
0
5
5
S
S
o
o
n
n
y
y
C
C
o
o
r
r
p
p
o
o
r
r
a
a
t
t
i
i
o
o
n
n
Page 1/43
Contents
Main
SRP-X500P
Table of Contents
1. Overview
1.1 About This Manual
1.2 Connecting the SRP-X500P to a Computer
1.3 Communication Format
1.4 Communication Protocol
1.5 RS-232C indicator
1.6 Note on Value Settings
1.7 Handshake Codes
ACK : 0x41 ( A )
NAK : 0x4E ( N )
DELIMITER : 0x0D ( CR )
1.8 Communication Packet Format
2. Command Reference
2.1 Basic Control Commands
2.1.1 AV/RGB INPUT SELECT : 0x43 0x53 0x45 0x4C (CSEL)
Packet format
Parameter
2.1.3 INPUT FADER : 0x43 0x50 0x4D 0x35 (CPM5)
FADER (1st-6th byte)
Example
2.1.4 INPUT FADER REQUEST : 0x52 0x50 0x4D 0x35 (RPM5)
Packet format
Return packet format
2.1.5 OUTPUT FADER : 0x43 0x50 0x4D 0x40 (CPM@)
Packet format
Parameter
FADER (1st-8th byte)
Example
2.1.7 REMOTE 1-6 LEVEL : 0x43 0x4C 0x56 0x4C (CLVL)
Packet format
Parameter
Channel (1st byte)
LEVEL (2nd byte)
2.1.8 REMOTE FADER LEVEL PARAMETER REQUEST : 0x52 0x4C 0x56 0x4C (RLVL)
Packet format
Return packet format
Parameter
MASTER VOLUME LEVEL (1st byte)
2.1.9 MASTER VOLUME UP : 0x43 0x4C 0x56 0x2B (CLV+)
Packet format
Parameter
Example
2.1.10 MASTER VOLUME DOWN : 0x43 0x4C 0x56 0x2D (CLV-)
2.1.11 MASTER VOLUME STOP : 0x43 0x4C 0x56 0x53 (CLVS)
2.1.12 MUTING : 0x43 0x4D 0x55 0x54 (CMUT)
Packet format
Parameter
Channel (1st byte)
MUTING (2nd byte)
2.1.13 MUTING PARAMETER REQUEST : 0x52 0x4D 0x55 0x54 (RMUT)
Packet format
Return packet format
Parameter
INPUT MUTING (1st byte)
LINE OUTPUT MUTING (3rd byte)
MASTER MUTING (4th byte)
REMOTE MUTING (5th byte)
Example
2.1.14 PROJECTOR ON/STANDBY : 0x43 0x50 0x4A 0x50 (CPJP)
Packet format
Parameter
PROJECTOR CONTROL REQUEST (1st byte)
Example
2.1.16 SCENE RECALL : 0x43 0x52 0x43 0x4C (CRCL)
Packet format
Parameter
SCENE RECALL REQUEST (1st byte)
Example
2.1.17 SCENE RECALL PARAMETER REQUEST : 0x52 0x52 0x43 0x4C (RRCL)
Packet format
Return packet format
Parameter
SCENE No. (1st byte)
2.2 Status Acquisition Commands
2.2.1 INDEX REQUEST : 0x52 0x50 0x4D 0x44 (RPMD)
Packet format
Return packet format
Parameter
2.2.2 LEVEL METER PARAMETER REQUEST : 0x52 0x4D 0x54 0x52 (RMTR)
Parameter
LEVEL METER (1st-16th byte)
Example
2.2.3 STATUS REQUEST : 0x52 0x50 0x4D specified value (RPMspecified value)
To acquire status of single item
Packet format
Example
Return packet format
Page
Parameters
PROJECTOR PROTOCOL SWITCH (1st byte) SYSTEM TYPE SWITCH (2nd byte)
INPUT VOLUME (3rd-8th byte)
MASTER VOLUME LEVEL (9th byte)
REMOTE 1-6 LEVEL (10th-15th byte)
INPUT LEVEL (16th-21st byte)
OUTPUT LEVEL (22nd-29th byte)
INPUT MUTING (30th byte)
OUTPUT MUTING (31st and 32nd byte)
SPEAKER OUTPUT MUTING
LINE OUTPUT MUTING
MASTER MUTING (33rd byte)
REMOTE MUTING (34th byte)
RF/AF INDICATOR (36th byte)
WL INDICATOR (37th byte)
+48V SWITCH (38th byte)
MIC 1-4 TRIM (39th-42nd byte)
LINE TRIM (43rd byte)
AV/RGB TRIM (44th-48th byte)
REF INDICATOR (49th byte)
FR (50th-53rd byte)
FR
FR SETUP STATUS (54th and 55th byte)
SETUP CHANNEL
SETUP STATUS
AV/RGB INPUT SELECT (56th byte)
SPEAKER OUTPUT LEVEL (57th, 58th byte)
IR OUTPUT MODE INDICATOR (59th byte)
LEVEL METER (60th-75th byte)
PROTECTION (76th byte)
CLIP INDICATOR (77th byte)
TEMPERATURE (78th and 79th byte)
TEMPERATURE
PROJECTOR ON/STANDBY INDICATOR (80th byte)
EMG MUTING (83rd byte)
SCENE No. (84th byte)
PARALLEL INPUT (85th-94th byte)
LEVEL
PARALLEL OUTPUT (95th and 96th byte)
OUTPUT 1-6
OUTPUT 7-10
FAN MOTOR (97th byte)
MASTER VOLUME CONTROL (98th byte)
GAIN REDUCTION (99th-108th byte)
AGC GAIN CONTROL
COMPRESSOR GAIN REDUCTION
2.3 Maintenance Information Commands
2.3.1 INFORMATION REQUEST : 0x52 0x50 0x4D 0x45 (RPME)
Packet format
Return packet format
Parameter
2.3.2 MAINTENANCE INFORMATION READ WRITE : 0x43 0x4D 0x49 0x31 (CMI1)
Packet format
Parameter
MAINTENANCE INFORMATION READ WRITE
Example
2.3.3 MAINTENANCE INFORMATION READ WRITE REQUEST : 0x52 0x4D 0x49 0x31 (RMI1)
Packet format
Return packet format
2.3.4 MAINTENANCE INFORMATION READ ONLY REQUEST : 0x52 0x4D 0x49 0x32 (RMI2)
Packet format
2.3.5 VERSION REQUEST : 0x52 0x56 0x45 0x52 (RVER)
Packet format
Return packet format
Parameter
VERSION
2.3.6 FACTORY PRESET : 0x43 0x52 0x53 0x54 (CRST)