Sony SRP-X500P manual FR 50th-53rd byte, FR Setup Status 54th and 55th byte, Setup Channel

Models: SRP-X500P

1 43
Download 43 pages 60.38 Kb
Page 31
Image 31

SRP-X500P RS-232C Interface Manual

FR (50th-53rd byte)

The FR parameter consists of the 4 bytes of data in the order shown in the following table.

Byte

Parameter

1st

MIC 1/WL 1 FR

2nd

MIC 2/WL 2 FR

3rd

MIC 3 FR

4th

MIC 4 FR

FR

Shows the status of the FEED BACK REDUCER. The correspondence of the parameter with the FEED BACK REDUCER setting is shown in the following table.

FR

Turned off

0x30 (‘0’)

Turned on

0x31 (‘1’)

Setting up in progress

0x32 (‘2’)

Cancellation in progress

0x33 (‘3’)

FR SETUP STATUS (54th and 55th byte)

The FEED BACK REDUCER setup status parameter consists of the 2 bytes of data in the order shown in the following table.

Byte

Parameter

1st

SETUP CHANNEL

2nd

SETUP STATUS

SETUP CHANNEL

Shows the channel for which the FEED BACK REDUCER setting is in progress.

The parameter and the channel are shown in the following table.

Channel

Normal operation

0x30 (‘0’)

MIC 1/WL 1

0x31 (‘1’)

MIC 2/WL 2

0x32 (‘2’)

MIC 3

0x33 (‘3’)

MIC 4

0x34 (‘4’)

CANCEL

0x35 (‘5’)

Page 31/43

Page 31
Image 31
Sony SRP-X500P manual FR 50th-53rd byte, FR Setup Status 54th and 55th byte, Setup Channel