For Machines Mfg. Since 8/09

M A I N T E N A N C E

Model SB1029

Maintenance Schedule

!

Always disconnect

 

machine from power before

 

performing maintenance or

 

serious personal injury may

 

result.

Recommended Lubricating Oil Types:

To avoid oil breakdown, DO NOT MIX OILS! If changing oil types, be sure to flush system with the new oil and discard the flushed oil.

ssMobil Vacuoline 1405 ss Mobil Vacuoline 1409 ss Shell Tonna 33

ss Shell Tonna 27

ss BP Energol HP 20-C

Daily:

ss #HECKCORRECTCLOOSERMOUNTING BOLTS

sCheck/correct damaged or cracked grinding wheel.

sCheck/correct worn or damaged wires.

ssClean/protect table.

ssVacuum metal shavings from machine. s Correct any other unsafe condition.

Bi-Annually:

ssChange lubrication oil, verify oil distribution setting.

ssClean and re-oil pinion gears.

Annually:

ssRemove pump screen and clean debris. ss Verify machine is level and readjust as

required.

Basic Lubrication

If this machine is used in a heavy industrial setting, or in a dirty or damp environment, increase the oil-change intervals.

If the machine is new or being put back into service from storage, you must first to flush the lubrication system with ATF Dextron II. Run the pump for 5-10 minutes, and move all handwheels through their full range of motion as the high detergent oil breaks down and flushes away storage grease from the bearings, ways, and galleys. When finished, drain and refill the oil system, and conduct a test run as outlined in this manual.

To lubricate your machine:

1.Read and take the appropriate safety measures covered in this manual.

2.Remove the screws and the left-side cabinet access plate, and fill the oil reservoir or replace the oil if it is dirty (see Figure 44).

Figure 44. Lubrication pump and reservoir.

3.Make sure the pinion gears and leadscrew (Figure 45) are wet with oil.

Pinion

Gears

Leadscrew

Figure 45. Lower leadscrew and pinion gears.

-33-