14" TURN-X®Toolroom Lathe

O P E R A T I O N

For Machines Mfg. Since 5/11

 

 

 

Thread Dial Chart

Find the TPI (threads per inch) that you want to cut in the left column of the thread dial chart (see Figure 80), then reference the dial number to the right of it. The dial numbers indicate when to engage the half nut for a specific thread pitch. The thread dial chart can also be found on the front of the thread dial housing.

In.

 

2

3

1

4

 

4,8,12,16,20,24, Any Position 28,32,36,40,44, 48,56,60,72

2,6,10,14,

Non-

18,22,26,

Numbered

30,54

Position

3,5,7,9,

Numbered

11,13,15,

Position

19,23,27

1,2,3,4

2½,3½,4½,

Position

7½,11½,13½

1,3 or 2,4

2¼,2¾,

Position

3¼,3¾

1 Only

278

Same as

 

Metric

 

Threads

Figure 80.Thread dial chart.

Note: The thread dial is not used for metric threading, or diametral and modular pitches. You must leave the half nut engaged from the beginning until the turning is complete for these types of operations.

The following examples explain how to use the thread dial chart.

TPI Divisible By 4

For threading a TPI that is divisible by four, use any line on the thread dial (see Figure 81).

TPI

4,8,12,16,20,24, Any Position 28,32,36,40,44, 48,56,60,72

Figure 81. Any position on the dial for threading TPI

divisible by 4.

Even TPI Not Divisible By 4

For threading a TPI that is even but not divisible by 4, use any of the non-numbered lines on the thread dial (see Figure 82).

TPI

2,6,10,14,

Non-

18,22,26,

Numbered

30,54

Position

Figure 82. Marks are selected on the dial for threading

even TPI not divisible by 4.

Odd Numbered TPI

For odd numbered TPI, use any of the numbered lines on the thread dial (see Figure 83).

TPI

 

 

 

3,5,7,9,

Numbered

11,13,15,

Position

19,23,27

1,2,3,4

Figure 83. Numbers are selected on the dial for

threading odd numbered TPI.

12 Fractional TPI

Use any opposing number pairs—2/4 or 1/3 on the thread dial for 12 fractional TPI (see Figure 84). For example, to cut a 312 thread, select 1 or 3 on the dial.

TPI

2½,3½,4½,

Position

7½,11½,13½

1,3 or 2,4

Figure 84. Opposing number group are selected on

dial for cutting 12 thread TPI.

-58-

Page 60
Image 60
Southbend sb1039 Thread Dial Chart, TPI Divisible By, Even TPI Not Divisible By, Odd Numbered TPI, ⁄2 Fractional TPI