14" | E L E C T R I C A L | For Machines Mfg. Since 5/11 |
|
|
|
Correcting Phase Polarity Wiring
This
To correct wiring that is out of phase:
1.Push the STOP button, turn the master power switch to OFF, and disconnect the machine from power.
2.Open the electrical box and swap any two hot wires coming from the plug, as illustrated in Figure 138.
| To Plug |
| Ground |
|
|
| |
Swap any two |
|
| Gn |
of these wires | Hot | Hot | Hot |
3 5 1
MASTER
POWER SWITCH
4 6 2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L1 |
| L2 |
| L3 |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 138. Swapping L1 and L2 power connections
to correct out-of-phase wiring.
3.Close and latch the electrical box, and reconnect the machine to the power source.