EVS Toolroom Lathe w/DRO | P R E P A R A T I O N | For Machines Mfg. Since 3/11 |
13.Move the spindle ON/OFF lever down to start the spindle rotating counterclockwise (down toward the front of the lathe).
—If the spindle rotates in the opposite direction (clockwise), the power supply phase polarity may be incorrect. Refer to Correcting Phase Polarity on Page 92 to resolve this.
14.Observe the lathe and listen for any abnormal noises or vibration. The lathe should run smoothly.
15.Push the STOP button. The spindle should come to a slow stop.
16.Move the spindle ON/OFF lever up to the OFF (middle) position, reset the STOP button by twisting it clockwise until it pops out, then restart spindle rotation by moving it down again.
17.Press the foot brake. The spindle should come to a quick stop.
—If the foot brake has no effect on the stopping speed of the spindle, push the STOP button and refer to Brake Service on Page 82 to adjust the brake.
18.Push the STOP button and move the spindle ON/OFF lever up to the OFF (middle) position to prevent accidental
19.Remove the end gear cover from the left side of the headstock. There is a safety switch that prevents the spindle from starting while this cover is removed.
20.Reset the STOP button, stand away from all the exposed gears on the side of the headstock, then attempt to start spindle
—If the spindle does start with the end gear cover removed, the safety limit switch is not adjusted or operating correctly. This safety feature must operate properly before continuing. Press the STOP button to turn the lathe OFF, disconnect it from power, and call Tech Support for help.
21.Push the STOP button in, move the spindle ON/OFF lever to the OFF position, then replace the end gear cover.
22.Reset the STOP button, then lift the chuck guard
—If the spindle starts with the chuck guard in the up position, the safety switch is not adjusted or operating correctly. This safety feature must operate properly before continuing. Press the STOP button to turn the lathe OFF, disconnect it from power, and call Tech Support for help.
23.Move the chuck guard back down into operating position.
24.Point the coolant nozzle down into the chip drawer and verify that there is coolant in the reservoir (refer to Coolant System Service on Page 75 for detailed instructions).
25.Use the coolant pump switch on the control panel to start the pump, then open the valve at the base of the nozzle. Verify that the coolant flows from the nozzle, then close the valve and turn the pump OFF.
Congratulations! The test run is complete. Perform the following Spindle