RAID Array 3000 Controller Shelf

Table 1–2 Shelf Technical Specifications (continued)

Feature

Maximum I/O per sec- ond

Sustained Raid 5 I/O rate -- 2 KB block transfers

RAID levels supported

Non-RAID disk support (JBOD)

Reconstruct time

Stripe size / chunk size

Maximum Logical Drives (LUNs)

Maximum disk/ RAID sets

Boot from RAID set

Passthrough to tape,

CD

Maximum number of disks

Maximum disks per device port

Global spare

Drive support

Redundant fans

Drive reconstruct

Disk hot swap

Redundant power supplies

Environmental moni- toring

Setup/control lines

Serviceability

RAID Manger GUI support

Description

4,400 I/O per second

Read -- 1,375 I/O per second per controller pair Write – 392 I/O per second per controller pair

0, 1, 0+1, 4, 5

Yes

Configurable with SWCC

Variable

Up to 30 RAID sets

Up to 16 redundancy groups (LUNs) per RAID set

Two, 32 blocks. Theoretical 2.2 petabytes; restricted by drive capacity

Yes, operating systems dependent

Not supported

24 in four disk shelves

12

Yes

2, 4, 9, 18 GB Wide UltraSCSI drives in SBB

Yes

Automatic with spare

Yes

Yes

Yes, monitors power and temperature

1 Serial per controller

Hot swap components

StorageWorks Command Console V2.0 (SWCC) available for all platforms.

1–20

EK–SMCPQ–UG. C01

Page 32
Image 32
Compaq 3000 manual Shelf Technical Specifications