3.3.3Cabling a Two Device Expansion Shelf Subsystem (See Figures 3–10 and 3–11)

1.Ensure the physical installation phase of installing and securing shelf brack- ets and shelves (including the UPS) has been accomplished and that the shelves are secured within the shelf bracket the shelf lock provided.

2.Remove the device I/O module from the Controller Shelf and ensure the switch positions of SCSI bus termination switch S4 are set as shown in Fig- ure 3–9. Replace the module in the Controller Shelf.

3.Remove the personality I/O module from Device Expansion Shelf # 1 and set SCSI bus termination switch S4 and SCSI bus address switch S3 on this module as shown in Figure 3–11.

4.Remove the personality I/O module from Device Expansion Shelf # 2 and repeat step 3.

5.Connect the black ac power cords (supplied with the shelves) from the ac power source to the outside power supply on each shelf (see Figure 3–10).

6.Connect the gray power cables from the inside power supply on each shelf to the power receptacles on the back of the UPS (ensure the UPS is connected to an ac source.

7.Connect a 0.5-meter SCSI cable (BN37A-0E) from the top SCSI connector on the Controller Shelf device I/O module (device bus 1) and the SCSI con- nector on the front of the personality I/O module on the Expansion Shelf.

8.Connect a second 0.5-meter SCSI cable (BN37A-0E) from the bottom SCSI connector on the Controller Shelf device I/O module (device bus 2) and the SCSI connector on the front of the personality I/O module on the Device Expansion Shelf # 2.

9.Connect a 5-meter SCSI cable (BN37A-05) between the host-inconnector on the Controller Shelf host 0 I/O module (bottom connector) and the corre- sponding connector on the host system.

10.Connect the maintenance serial control cable (17-04730-01) from the CTR 0 connector on the Controller Shelf host 0 I/O module to the corresponding connector on the maintenance PC.

11.Connect the UPS serial control cable (17-04729-01) from the UPS connector Controller Shelf host 0 I/O module to the like connector on the UPS.

12.Install jumper connector 12-49700-01 to the Controller Shelf UPS connector on the host 1 I/O module.