EVS Toolroom Lathe w/DRO

Thread Dial

The numbers on the thread dial are used with the thread dial chart to show when to engage the half nut during inch threading. The thread dial gear must be engaged with the leadscrew for this to work. Loosen the knurled knob on the thread dial, pivot the dial gear toward the leadscrew

so that it properly meshes with the leadscrew threads, then re-tighten the knob, as shown Figure 80.

Leadscrew

Dial Gear

Knurled

Knob

Figure 80. Thread dial engaged with the leadscrew.

Thread Dial Chart

Find the TPI (threads per inch) that you want to cut in the left column of the thread dial chart (see Figure 81), then reference the dial number to the right of it. The dial numbers indicate when to engage the half nut for a specific thread pitch. The thread dial chart can also be found on the front of the thread dial housing.

In.

 

2

3

1

4

4,8,12,16,20,24,

Any Position

28,32,36,40,44,

 

48,56,60,72

 

2,6,10,14,

Non-

18,22,26,

Numbered

30,54

Position

3,5,7,9,

Numbered

11,13,15,

Position

19,23,27

1,2,3,4

2½,3½,4½,

Position

7½,11½,13½

1,3 or 2,4

2¼,2¾,

Position

3¼,3¾

1 Only

278

Same as

 

Metric

 

Threads

Figure 81. Thread dial chart.

When threading, we recommend using the slowest speed possible and avoiding deep cuts, so you are able to disengage the half nut when required and prevent an apron crash!

Note: The thread dial is not used for metric threading, or diametral and modular pitches. You must leave the half nut engaged from the beginning until the turning is complete for these types of operations.

The following examples explain how to use the thread dial chart.

TPI Divisible By 4

For threading a TPI that is divisible by four, use any line on the thread dial (see Figure 82).

TPI

4,8,12,16,20,24, Any Position 28,32,36,40,44, 48,56,60,72

Figure 82. Any position on the dial for threading TPI

divisible by 4.