Installation

Pre-Installation Inspection

Upon delivery, visually inspect the packaging and portions of the product visible through the packaging for shipping damage. If the package or product is damaged, or if signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.

Remove the packaging as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.

IMPORTANT: Remove the shipping tape from the two backdraft dampers located in the exhaust outlet.

IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.

Materials Required (Obtain Locally)

All Models

One fused disconnect switch or circuit

 

breaker.

 

 

Gas Models

One gas shut-off valve for gas service

 

line to each tumbler.

Steam Models One steam shut-off valve for steam service line to be connected upstream of solenoid steam valve.

Two steam shut-off valves for each condensate return line.

Flexible steam hoses with a 125 psig (pounds per square inch gauge)

(8.79 kg/sq. cm) working pressure for connecting steam coils. Refer to Figure 15 for sizing and connection configurations.

Two steam traps for steam coil outlet to condensate return line.

Two vacuum breakers for condensate return lines.

IMPORTANT: Keep tumbler area clear and free from combustible materials, gasoline and other flammable vapors and liquids.