Installation
Location Requirements
The tumbler must be installed on a level floor. Floor covering materials such as carpeting or tile must be removed.
To assure compliance, consult local building code requirements.
The tumbler MUST NOT be installed or stored in an area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note that the enclosure touches the tumbler top and side panels. Also, note the minimum and maximum dimensions. There may be local codes and ordinances which must be complied with.
WARNING
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
W055
IMPORTANT: Install tumblers with sufficient clearance for servicing and operation. Refer to Figure 1.
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.
|
|
|
|
| W056 |
|
|
| |||
2 | 3 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1
4

5
7 | 6 | TMB815N |
| ||
|
|
TMB815N
NOTE: Shaded areas indicate adjacent structure.
1Zero Clearance Permitted for First 4 in. (102 mm)
24 in. (102 mm) Maximum Header Thickness
312 in. (305 mm) Minimum Clearance Permitted for Remainder
4Guard
5Provision for
624 in. (610 mm) Minimum – 36 in. (914 mm) Recommended for Maintenance Purposes
7Zero Clearance
Figure 1
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70256801 |