Steam Requirements

2

1

12

11

3

13

4

10

9

8

7

6

5

T221I

NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows.

1

Supply

8

18 in. (457 mm) Drop

2

12 in. (305 mm) Riser

9

Solenoid Valve (Supplied with machine)

3

Globe Valve

10

Steam Bonnet

4

Return

11

Check Valve

5

Check Valve

12

Union

6

Condensate Return Line from Supply Line

13

Trap with Built-In Strainer

7Vacuum Breaker

Figure 15

 

 

 

Steam Trap Size

Model

Steam Pressure (psi)

Minimum Pipe Diameter

(Pounds Condensate/

 

 

 

Hour)

 

 

 

 

CSL

7-15

3/4 in. (19 mm)

140

 

 

 

 

CSH

80-100

3/4 in. (19 mm)

160

 

 

 

 

Table 11

40

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70256801