Installation
Removal of Existing Timing Cam1.Rotate cam by hand until “V” notch lines up beneath the ratchet tooth. Refer to Figure 3.
2.Insert narrow screwdriver under nylon cam, close to the clock shaft. Lift gently off shaft. Make sure that pressure is directed upward and that the “V” notch clears the ratchet tooth.
Installation of New Timing Cam1.Insert drive fork into timing cam with wide prong in wide hole of cam.
2.Position timing cam and drive fork over the timer shaft, aligning the timer flat with the drive fork and the “V” notch with one of the ratchet teeth.
3.Press timing cam down firmly to seat timing cam onto the motor shaft.
4.Remove all accumulated time by turning cam counterclockwise until switch shuts off. Apply moderate clockwise pressure to fully seated timing cam and drive against the timing motor shaft. Meter must be advanced electrically for one cycle before an accurate measure of time can be made.
1
2
T039I
T039I
1Line Up Notch to Clear Ratchet Tooth
2Lift Gently with Narrow Blade
Figure 3
18 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70256801 |