Installation
Basic Configuration1.Determine the necessary conversion operations to convert from the
2.Perform the conversions required so the machine is properly configured for the desired country and gas (refer to Specific Conversion Procedures
Section):
●How to Convert Gas Valve from Regulated to Unregulated
NOTE: Conversion from regulated to unregulated is only needed when regulated tumblers were ordered, but unregulated tumblers were needed.
●How to Change Injector (Orifice) Size
●How to Adjust Gas Valve Governor/Regulator
3.If applicable, peel off the appropriate country sticker from Part No. 503382 (included with machine) and apply it to the serial plate over the existing country information. Refer to Figure 9.
4.If applicable, peel off the appropriate conversion sticker from Part No. M413800 (included with machine) and apply it to the serial plate over the “ADJUSTED FOR ______ GAS: ______” information. Refer to Figure 9.
WARNING
When converting the tumbler to a different gas or pressure, first verify that the supply inlet pressure is equipped with a pressure regulator (located ahead of the tumbler) that will maintain the gas supply at the inlet pressure specified.
W430
SPECIFIED
LOCAL INLET
PRESSURE
2
3
1
T103K
1Gas
2Pressure Tap
3Gas
Figure 5
Specific Conversion ProceduresHow to Convert Gas Valve from Regulated to Unregulated
NOTE: Conversion from regulated to unregulated is only needed when regulated tumblers were ordered, but unregulated tumblers were needed.
Johnson G96 Gas Valve:
a. Disconnect electrical power from tumbler. Close gas
b. Follow instructions in Conversion Kit, Part No. M400763 (Johnson Part No.
NOTE: This kit does not contain any orifices.
c. Change injector size as required by the appropriate table according to How to
Change Injector (Orifice) Size.
d. Commission tumbler for use.
22 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70256801 |