Installation
Model 50CG
Gas |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Gas | Inject. | Inject. Qty | Inlet | Gvnr./ | Inject. | |
GB | IE | PT | ES | IT | DK | NO | SE | FI | DE | NL | BE | FR | AT | Family & | |||||||
Type | 0 | & Part. No. | Press. | Regltr. | Press. | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Group | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2nd family |
| 2 |
|
|
| |
| 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 |
|
|
| 2 | Group H | 3.7 mm | 20 mbar | Yes | 8.9 mbar | ||
|
|
|
| M401000 | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (E) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Nat. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2nd family |
| 2 |
|
|
| |
Gas |
|
|
|
|
|
|
|
|
|
| 3 |
|
|
| Group L | 3.7 mm | 25 mbar | Yes | 12.6 mbar | ||
|
|
|
|
|
|
|
|
|
|
|
|
| M401000 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (LL) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| 4 | 4 |
| 2nd family | 3.0 mm | 2 | 20.25 | No | Unreg. | |
|
|
|
|
|
|
|
|
|
|
|
|
| Group E+ | M401017 | mbar | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3rd family |
| 2 |
|
|
| |
|
|
|
|
|
| 5 | 5 | 5 | 5 | 5 | 5 |
|
|
| Group | 2.1 mm | 30 mbar | No | Unreg. | ||
|
|
|
|
|
|
|
|
| M401003 | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B/P |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
L.P. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3rd family |
| 2 |
|
|
| |
Gas |
|
|
|
|
|
|
|
|
| 6 |
|
|
| 6 | Group | 2.1 mm | 50 mbar | Yes | 28.5 mbar | ||
|
|
|
|
|
|
|
|
|
|
|
| M401003 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B/P |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 7 | 7 | 7 | 7 | 7 |
|
|
|
|
|
| 8 | 8 |
| 3rd family | 2.1 mm | 2 | 28.37 | No | Unreg. | |
|
|
|
|
|
|
|
| Group 3+ | M401033 | mbar | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 3
NOTE: Follow all instructions including verification and adjustment of injector pressure.
1 – Order as Regulated Natural Gas. No modification needed.
2 – Order as Regulated Natural Gas. Apply appropriate country sticker.
3 – Order as Regulated Natural Gas. Apply appropriate country and gas stickers.
4 – Order as Unregulated Natural Gas. Apply appropriate country sticker.
5 – Order as Unregulated L.P. Gas. Apply appropriate country sticker.
6 – Order as Regulated Natural Gas. Convert with regulator spring kit Part No. M411334 and (2) 2.1 mm injectors Part No. M401003. Apply appropriate country and gas stickers.
7 – Order as Unregulated L.P. Gas. No modification needed.
8 – Order as Unregulated L.P. Gas. Apply appropriate country sticker.
OPEN – No Approval available.
Special Cases – Regulated Gas Valve may be converted to Unregulated with
70256801 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 25 |