Gas Requirements

Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive leak detection fluid. Purge air in gas service line by operating the tumblers in the drying mode. If burner does not light and unit goes into lockout, open and close the door and restart. Repeat these steps until burner ignites. Use pipe compound, resistant to

actions of L.P. Gas, on all pipe threads.

WARNING

Do not use an open flame to check for gas leaks! To reduce the risk of explosion or fire check all pipe connections, internal and external, for gas leaks using a non- corrosive leak detection fluid. Check gas connections annually for leakage.

W408

1

2

3

 

 

4

5

8 7

6T378I

T135I

1Gas Line to Tumbler

21/8 in. NPT Plug

3Gas Supply Piping System

4Gas “T” Fitting

56 in. (152 mm) Minimum Gas Pipe

6Gas Pipe Cap

7Dirt and Water Vapor Trap

8Shut-Off Valve

Figure 13