Airflow Switch

Gas and Electric Tumblers

WARNING

To reduce the risk of fire, airflow switch operation may be affected by a clogged lint screen, lack of make-up air, obstructions in the vertical recirculation stack or in the customer installed main or collector ducts. These conditions must be checked and necessary corrections made before adjusting airflow switch. Always adjust airflow at installation.

W073

The airflow switch (located on the rear of tumbler, Figure 19) is set at the factory for proper operation. However, if there is a problem with the switch, it should be adjusted as follows:

NOTE: Steam models do not have an airflow switch.

NOTE: Control panel must be in place and access door closed before attempting to adjust airflow switch.

IMPORTANT: Airflow switch disc must remain closed during operation. If it opens and closes during the drying cycle, this indicates insufficient airflow through the tumbler. If switch remains open, or pops open and closed during the cycle, the heating system will shut off. The cylinder and fan will continue to operate even though the airflow switch is opened.

Adjustments

The airflow switch operation is controlled by the counterweight position in the shaft. Moving the counterweight either increases or decreases airflow switch sensitivity. The counterweight should be adjusted so the disc moves away from the cabinet when the lint panel is opened 1.5 inches (38.1 mm) with a full load. Adjust the airflow switch as follows:

1.Load the tumbler. This adjustment is much faster to make with one person opening lint panel in front and another adjusting the counterweight in the rear of tumbler.

2.Start the tumbler. Open the lint panel 1.5 inches (38.1 mm). The airflow disc should move away from the cabinet, opening the switch contacts and shutting off the heat system. This indicates proper operation and proper adjustment.

3.If switch is not opening as described in step 2, it should be adjusted so it is MORE sensitive. Depress the spring clip and move counterweight toward disc. Retest by opening lint panel and continue moving counterweight toward disc until switch operates as described in step 2.

4.If switch opens BEFORE lint panel is opened the proper distance, step 2, it should be adjusted so it is LESS sensitive. Depress the spring clip and move counterweight away from the disc. Retest by opening lint panel and continue moving counterweight away from disc until switch operates as described in step 2.

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

47