Star Micronics SP2000 manual Peripheral Device Control, Function

Models: SP2000

1 81
Download 81 pages 44.24 Kb
Page 33
Image 33
1-2-5. Peripheral Device Control

1-2-5. Peripheral Device Control

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

Defines drive pulse width for peripheral device #1

<ESC> <BEL> n1 n2 (1B)H (07)H n1 n2

1 <= n1 <= 127, 1 <= n2 <= 127 (default setting n1 = n2 = 20)

Adjusts drive pulse width for peripheral devices requiring other than standard 200 ms pulse time and delay time Energizing time = 10 X n1 (ms)

Delay time = 10 X n2 (ms)

Executed by <BEL>, <FS> codes.

10 x n1 (ms)

10 x n2 (ms)

FUNCTION

CODE

OUTLINE

NOTE

Printing and paper feed are prohibited.

Controls peripheral device #1

<BEL>

(07)H

Executes drive pulse for peripheral unit 1 (deferred).

Peripheral Units 1 and 2 cannot be driven simultaneously.

31

Page 33
Image 33
Star Micronics SP2000 manual Peripheral Device Control, Function