FUNCTION

CODE

OUTLINE

Transmits EOT status

<EOT>

(04)H

Transmits the EOT status of the printer to the host in real-time.

(Does not execute after taking fro reception buffer, but immedi- ately upon receiving from the host.) It is in a “Data ready” state when using a bi-directional parallel interface.

When one <EOT> command is sent to the printer, it will not send the next <EOT> command until the EOT status is received.

When using the <EOT> command, always set the automatic status function to invalid.

EOT Status

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

(Always 1)

Bit 2: Paper Near End

1: Near End

Bit 3: No Paper Error (Same as ENQ Bit 3) 1: Error

Bit1, Bit 5 to Bit 7 statsu unknown