Image 45

Instruction Manual

Mouse Synchronization

At times, the local mouse movement may lose sync with the remote mouse movement. You can try getting them back in sync with fast mouse synchronization by moving the mouse pointer down into the Java Applet toolbar. If that does not help, run Auto sync (as discussed on the previous page).

1.If Auto sync does not resolve the problem, the Mouse Synchronization function can get them back into sync. This is similar to the Mouse Synchronization feature of the Windows Client.

2.Click the Mouse Synchronization button. The remote mouse pointer moves to the upper left area of the screen.

3.Move your local mouse pointer directly over the remote mouse pointer and Click. mouse adj.

The Message Board

Please refer to pg. 34 for a detailed explanation of the Message Board function.

Administrator Reset

The following procedure will reset the default username and password in the event that the Username and Password information has become corrupted or lost.

To clear the login information (and return all settings to their defaults), do the following:

1.Disconnect the power adapter and all cables.

2.Remove the housing from the SV1107IPEXT.

3.Short jumper J9 on the circuit board.

4.Reconnect the SV1107IPEXT power adapter.

41