6.non recessed installation

INSTALLATION INSTRUCTIONS

INSTALLATION

1

A

B

 

AR1435

 

5.2Gas pipe entry must come through the rear right-hand side of the box. The rubber seal must be cut using a sharp knife to allow the isolating elbow to pass through it.

Ensure the rubber is not damaged when doing this,

Diagram 1, arrow B.

A means of isolation is provided with the appliance. This must be fitted to the supply pipe prior to installing the firebox.

The appliance can either be recessed into an inner leaf of the wall. A 75mm rebate surround must be used with this method. Or it can be installed in front of the wall in conjunction with a fire surround constructed of a studwork frame, Diagram 2 for options.

2

AR1428

AR1429

6.non recessed installation

6.1• Mark the position of the flue on the inner wall by measuring from the top of the finished hearth level, Diagram 3.

3

AR1436

6.2A 152mm (6’) diameter hole is required to install the flue. This can be achieved by either:

a)Core drill

b)Hammer and chisel.

It is advisable to drill small holes around the circumference when using method b. Make good both ends of the hole.

6.3It will now be necessary to construct a studwork frame to house the appliance. The minimum depth of the aperture must be 237mm. This includes an air gap of 5mm behind the appliance. The sides must be lined with non- combustible material for the full depth of the aperture.

6.4Combustible parts of the studwork frame must not be any closer than the minimum dimensions shown in Diagram 4. These dimensions need to be maintained even if the frame work is protected by non combustible material.

6.5Do not pack the void around or above the appliance with insulation material such as mineral wool.

4

AR1430

AR1431

17