IGNITION FUNCTIONAL CHECK 2

25

IGNITION FUNCTIONAL CHECK 2

NO SPARK

Ensure there is no debris around the pilot assembly,

(e.g. soot etc.) which could short the spark, clean the area.

 

 

 

 

Consult the users

 

 

 

 

 

instructions, retry.

 

 

From Ignition Fault

No

Is the valve being

Yes

 

 

 

 

Finding Chart 1

 

 

operated correctly?

 

 

 

 

 

Yes

 

 

 

 

 

Is the gap between

 

No

 

 

 

electrode and

 

Reset the electrode gap, retry.

 

 

thermocouple 4.0mm?

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

Has ignition lead

 

Yes

 

 

 

become detached or is

 

Correct and retry.

 

 

 

 

 

 

connection poor?

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

Remove the electrode lead

 

 

Check for defective or

 

 

 

 

damaged control knob spindle

 

Yes

from electrode with insulated

 

 

or cam operation. Check for

 

pliers. Hold the tip 3.5mm from the

 

correct location of piezo

 

 

 

 

 

pilot pipework, is there a spark

 

 

components. Correct and retry.

 

 

when the valve ‘clicks’?

 

 

 

 

FLAME FAILURE FUNCTIONAL CHECK 3

PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE

Ensure there is no debris around the pilot assembly,

(e.g. soot etc.)

Light the pilot and keep the control knob pushed in

at least 10 seconds before letting go.

 

 

 

 

 

No

 

Will pilot

 

Yes

 

 

 

With the pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stay alight?

 

 

 

 

 

 

 

With the fire running

running is the gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on full is the gas at

pressure as stated on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

No

the pressure stated

the databadge?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on the databadge?

 

 

 

 

 

 

 

 

Problem is with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pipework or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fittings which lead

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

to the fire. Correct

 

 

 

 

 

 

Yes

 

 

 

 

 

 

and retry.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run for 3 mins,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turn off, time interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

until mag unit shuts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

with a click. Is this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

greater than 7

Is the pilot flame of the

 

 

 

 

 

 

Is thermocouple

 

 

 

 

 

 

 

seconds?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection good

 

 

 

 

 

 

 

 

 

 

correct length?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in back of valve?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

Tighten the

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection and retry.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

SERVICING INSTRUCTIONS FAULT FINDING CHARTS

No

Is the electrode wire

detachable from the piezo

in the valve?

 

Remove the electrode lead from

 

the piezo. Place a small insulated

Yes

screwdriver close to the piezo

 

connection and operate the

 

No

Replace thermocouple.

No

Replace the valve.

valve. Does a spark jump from

the piezo to the valve body?

Yes

Change the pilot injector.

Will pilot

stay alight?

No

Change mag

unit.

Yes

No

Run for 3 mins, turn off, time interval until mag unit shuts with a click. Is this greater than 7 seconds?

Yes

Replace the electrode.

Replace the electrode

lead and retry.

 

SYSTEM OK