SERVICING INSTRUCTIONS
REPLACING PARTS
•Undo the two screws securing the valve to the bracket,
Diagram 17, Arrow E. The valve can now be removed.
17
E
|
|
|
|
| B | AR1434 | |
D | C A | ||||||
|
|
10.Mag unit
10.1Undo the thermocouple nut, Diagram 18, Arrow A.
18 |
|
A | AR1434 |
•Undo the mag unit retaining nut at the back of the control valve behind the thermocouple nut
After removing the retaining nut, the mag unit can be tapped out and a replacement fitted.
•Replace the mag unit retaining nut and tighten. Note - this is a
•Replace the thermocouple and check for gas leaks
10.2After reassembly, carry out the flame failure functional check as detailed in the flow chart, especially the mag unit drop out time.
11.Main injector
11.1• Undo the two nuts securing the injector pipe, Diagram
19
19 |
AR1433 |
•Rotate the injector until it is fully removed
•Replace with the correct replacement injector. When ordering, always state the model, gas type and serial number.
•Reassemble and turn the gas supply on, check for any leaks
12.changing between gas types
The following parts must be changed when converting an appliance from one gas type to another:
|
|
|
|
| ||
|
|
|
|
|
|
|
BURNER | NG |
| A8692 | NG |
| GZ6398 |
ASSEMBLY |
|
|
|
|
|
|
LPG |
| AP8692 | LPG |
| GZ6960 | |
|
|
| ||||
DATABADGE |
|
| PR0393EBF |
|
|
Note: The control valve will be set for the particular appliance and gas type. In all instances, when ordering new parts, be sure to quote the appliance type and serial number.
Use only genuine Gazco replacement parts.
30