Stovax PR0776 manual Cleaning The Fire, 5A. CLEANING THE E-STUDIO, 5B. CLEANING THE E-BOX

Models: PR0776

1 33
Download 33 pages 21.51 Kb
Page 5
Image 5
CLEANING THE FIRE

USER INSTRUCTIONS

TIMER MODE it will turn the fire on and off according to pre-set programme and automatically regulate the room temperature during the two periods. GAZCO PART NO. 8456.

CLEANING THE FIRE

ENSURE THE FIRE IS COLD BEFORE PROCEEDING

5.1• Refer to the separate Frame Instructions to remove the frame from the fire.

5A. CLEANING THE E-STUDIO

5.2• Remove the glass window by unscrewing the 8 screws in the glass window frame, Diagram 2

2

AR1996

5.3To clean the glass surface, Gazco recommends you use a ceramic glass product generally sold for cleaning ceramic hobs.

Remove the granite chippings and place on a dry clean surface. Do not remove the enamel back panel

Use a damp cloth and mild non-abrasive cleaner on the enamel back panel

Clean the burner and tray assembly using a vacuum cleaner with a soft brush attachment

Ensure all debris is removed from the burner ports

Replace the granite chippings by referring to Section 6A for E-Studio.

5B. CLEANING THE E-BOX

5.4• Remove the glass window by loosening the four screws in the lower retaining bracket

• Remove the four top screws and retaining bracket. The glass window can now be lifted clear. See diagram 3.

3

AR1465

AR1423

5.5To clean the glass surface, Gazco recommends you use a ceramic glass product generally sold for cleaning ceramic hobs.

Remove the ceramic coals or pebbles and fuel bed and place on a dry clean surface

Clean the burner and tray assembly using a vacuum cleaner with a soft brush attachment

Ensure all debris is removed from the ports

Replace the ceramics by referring to section 6B

ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS

The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.