Stovax PR0919 manual Flue Options Studio 1 BF, Studio 2 BF, TOP Flue UP & OUT KIT

Models: PR0919

1 33
Download 33 pages 9.39 Kb
Page 12
Image 12

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

2. FLUE OPTIONS

STUDIO 1 BF

1A

AR1671

STUDIO 2 BF

1A

AR1971

Start of bend to centre line of horizontal flue 170mm. Centre line of vertical flue to end of bend 220mm.

2.1 TOP FLUE UP & OUT KIT

STUDIO 1 BF (8534/8534AN)

Vertical from the top of the appliance then horizontally out. (See Diagram 1A). The basic kit comprises:

1 x 200mm vertical length

1 x 500mm terminal length (cut to length on site)

1 x 90° elbow

1 x wall plate

1 x 70mm restrictor

1 x 60mm restrictor

STUDIO 2 BF (8509/8509AN)

1 x 200mm vertical length

1 x 500mm vertical length

1 x 500mm terminal length (cut to length on site) 1 x 90° elbow

1 x wall plate

1 x 75mm restrictor

The kit may be used on its own. (Note – STUDIO 1 BF with a 200mm rise only the 500mm terminal length can be used). Extra lengths may be added to the vertical and horizontal from the list below.

1B

When A = 1.0 to 1.499 metes B & C = 1.0 metres maximum

When A = 1.499 metres to 3.0 metres B & C = 4.0 metres maximum

AR1672

2.2TOP FLUE UP & OUT WITH ADDITIONAL BEND

Any additional bend may be used on the horizontal section (either 45° or 90°), but the overall horizontal flue run will be reduced. Refer to Diagram 1B.

12

Page 12
Image 12
Stovax PR0919 manual Flue Options Studio 1 BF, Studio 2 BF, TOP Flue UP & OUT KIT, TOP Flue UP & OUT with Additional Bend