INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1C

AR1673

2.3 TOP FLUE VERTICAL KIT (8524/8524AN)

Vertical from the top of the appliance (See Diagram 1C).

A minimum vertical rise 3m (9’10") to a maximum 10m (32’10"). The basic kit comprises:

2 x 1m lengths

1 x 1m terminal length

1 x 52mm restrictor

1 x 47mm restrictor

1 x 60mm restrictor

Extra lengths may be added from the list below.

2.4TOP FLUE VERTICAL OFFSET KIT (8530/8530AN)

Used with kit 8524. A minimum rise of 500mm (191/2) is required to the first bend. See Diagram 1C.

2.5 EXTRA FLUE LENGTHS

All flue components are 150mm diameter (6")

NOMINAL

ACTUAL

STAINLESS

ANTHRACITE

LENGTH

LENGTH

FINISH

FINISH

200mm

140mm

8527

8527AN

500mm

440mm

8528

8528AN

1000mm

940mm

8529

8529AN

40° Bend

N/A

8507

8507AN

90° Bend

N/A

8508

8508AN

 

 

 

 

 

 

 

 

NOTE: Carefully consider:

a)Terminal positions

b)Flue supports

c)Weatherproofing

d)Fire precautions

For all the above options, you must conform to local and national codes of practice .

3. GAS SUPPLY

This appliance is intended for use on a gas installation with a governed meter.

3.1Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

3.2Ensure the gas supply delivers the required amount of gas and is in accordance with the rules in force.

3.3You can use soft copper tubing on the installation and soft soldered joints outside the appliance and below the fire.

3.4A factory fitted isolation device is part of the inlet connection; no further isolation device is required.

3.5All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance.

3.6The gas supply enters through the silicone panel located on the LEFT-HAND side of the outer box:

• Slit with a sharp knife prior to pass the supply pipe through.

3.7The gas supply must be installed in a way that does not restrict the removal of the appliance for servicing and inspection.

4.VENTILATION

4.1This appliance requires no additional ventilation.

13

Page 13
Image 13