7.COMMISSIONING

7.1Complete the Commissioning Checklist at the front of this manual covering:

Flue checks

Gas checks

Pebble layout - flame picture

For working pressure test, use the access panel at the gas connection ensuring the burner is in position.

7.2In the unlikely event that the appliance is receiving interference from other electronic devices, re-programme the handset/Control box

Reprogramming handset/Control box

Remove the battery cover from the handset to see the four DIP switches. See diagram29

29

AR1935

Each of the four switches can be set to either one of two positions, in any combination.

To re-code the handset

Change the combination of how the DIP switches are set.

For example see diagram20

30

AR1936

Once the handset has a new code the control box needs to be reprogrammed:

To access the control box see Servicing Instructions, Section

7- Main Control Assembly.

Press and hold the reset button on the control box until you hear two signals. After the second longer signal:

Release the reset button and within 20 seconds

Press the DOWN button on the handset until you hear an additional long signal confirming the new code

22