INSTALLATION INSTRUCTIONS
COMMISSIONING
7.COMMISSIONING
7.1Complete the Commissioning Checklist at the front of this manual covering:
•Flue checks
•Gas checks
•Pebble layout - flame picture
For working pressure test, use the access panel at the gas connection ensuring the burner is in position.
7.2In the unlikely event that the appliance is receiving interference from other electronic devices,
Reprogramming handset/Control box
•Remove the battery cover from the handset to see the four DIP switches. See diagram29
29
AR1935
Each of the four switches can be set to either one of two positions, in any combination.
To
•Change the combination of how the DIP switches are set.
For example see diagram20
30
AR1936
Once the handset has a new code the control box needs to be reprogrammed:
To access the control box see Servicing Instructions, Section
7- Main Control Assembly.
•Press and hold the reset button on the control box until you hear two signals. After the second longer signal:
•Release the reset button and within 20 seconds
•Press the DOWN button on the handset until you hear an additional long signal confirming the new code
22