Stovax PR0919 manual Gas Valve, magnetic safety valve, Control Box, Servicing Instructions

Models: PR0919

1 33
Download 33 pages 9.39 Kb
Page 29
Image 29
10.GAS VALVE

SERVICING INSTRUCTIONS

REPLACING PARTS

10.GAS VALVE

10.1To change the gas valve:

Remove the control assembly, Section 7

Release the gas inlet pipe, Diagram 18, Arrow A

Remove the thermocouple from the interrupter block

and release the second thermo current cables

Release the pilot pipe, Diagram 18, B

Release the injector feed pipe, Diagram 18, C

Remove the wire cable, Diagram18, D

Remove the two screws

The valve can now be freed.

18

B

 

A

11.magnetic safety valve C

D

AR1873

 

11.magnetic safety valve

11.1To replace the magnetic safety valve:

Undo the thermocouple from the interrupter block and remove the two thermo current cables

Unscrew the interrupter block from the back of the valve

Undo the silver magnetic valve retaining but on the back of the valve.

Gently tap out the mag valve

Replace with a new unit

Reassemble in reverse order

12.CONTROL BOX

Remove the two thermo current cables by removing the two screws, Diagram 19

Remove the ignition lead, Diagram 19

Remove the eight loom wire from the control box,

Diagram 19

19

Eight wire

 

cable

 

Thermo current

cables

Ignition lead

Touch pad extension cable

Battery 12.CONTROL BOXextension cable

AR1915

Remove the battery extension cable, Diagram 19

Remove the touch pad extension cable

The control box can now be replaced.

After replacing the control box you may need to reprogram the handset:

Press and hold the reset button on the control box until you hear two signals. After the second longer signal:

Release the reset button and within 20 seconds

Press the DOWN button on the handset until you hear an additional long signal confirming the new code

29

Page 29
Image 29
Stovax PR0919 manual Gas Valve, magnetic safety valve, Control Box, Servicing Instructions, Replacing Parts