Sun Microsystems 96257 manual Table A-5. Array Drive Module Status Descriptions, Status Code

Models: 96257

1 118
Download 118 pages 44.52 Kb
Page 73
Image 73

 

 

 

Array Drive Module Status Descriptions

Table A-5. Array Drive Module Status Descriptions

Drive Module Status

Status Code

 

Meaning/Description

 

 

 

Production Partition

Production: Active

P.A (PA)

Drive is active.

 

 

 

 

 

Drive is inactive and marked as broken. After its data is moved to

Production: Broken

P.B (PB)

a spare, broken drive is removed from Production partition and

 

 

put in ‘Unavailable: Broken’ (U.B) state.

Production: Copy

P.C (PC)

Drive is receiving data from drain of Production drive.

 

 

 

Production: Draining

P.D (PD)

Drive is being drained.

Production:

P.I (PI)

Drive is part of array initialization process.

Initialize Array

 

 

 

 

 

 

 

 

Drive is awaiting drain, but drain cannot start because:

Production:

P.P (PP)

Broken-to-spare data reconstruction is in progress

Another drive in the array is being drained

Pending Drain

 

 

The number of spares is inadequate (occurs if number of

 

 

 

spares was reduced after drain request was accepted).

Production:

P.R (PR)

Data from broken drive is being reconstructed on spare drive,

Reconstruction

which moves to ‘P.A’ state when reconstruction finishes.

 

 

 

 

 

 

Drive is broken but cause is unknown. Usually means data is be-

Production:

P.? (P?)

ing reconstructed to a spare, but may indicate other unknown

Unknown Drive State

state. After its data is moved, the broken drive moves from the

 

 

 

Production partition to an ‘Unavailable: Broken’ (U.B) state.

 

Media Acceptance Test (MAT) Partition

MAT: Active

M.A (MA)

Drive is active and available for allocation as a spare.

 

 

 

MAT: Fenced

M.F (MF)

Drive is fenced because GFR function is in progress.

 

 

Drive is not active due to diagnostic error. After failure is isolated,

MAT: Drive Not Ready

M.? (M?)

broken drive is removed from MAT partition and put in ‘Unavail-

 

 

able: Broken’ (U.B) state.

 

 

 

 

 

 

 

Spares Partition

Spare: Active

S.A (SA)

Drive is available to form arrays, reconstruct data, or receive da-

ta from drain operation.

 

 

Spare: Fenced

S.F (SF)

Drive is fenced for drive test.

 

 

 

Spare: Pending Drain

S.P (SP)

Drive is awaiting drain pending completion of drive test.

 

 

Drive is not active for unknown reason (possible failure). After

Spare: Drive Failure

S.? (S?)

failure is isolated, broken drive is removed from Spares partition

 

 

and put in ‘Unavailable: Broken’ (U.B) state.

 

 

 

 

 

 

 

Unavailable Partition

Unavailable: Broken

U.B (UB)

Drive is broken.

Unavailable: Isolated

U.I (UI)

Drive is isolated from the SSA loop configuration.

 

 

 

 

Unavailable:

U.N (UN)

No active drive is sensed in this slot.

No Active Drive Module

Unavailable:

U.S (US)

No drive is installed in this slot.

Slot Not Installed

 

 

 

 

 

 

 

96257

Sun Confidential: Internal Only

A-73

 

Revision A

 

Page 73
Image 73
Sun Microsystems 96257 manual Table A-5. Array Drive Module Status Descriptions, Status Code, Meaning/Description