Chapter 2: Server Installation

2-5 Checking the Motherboard Setup

After you install the 6012P-6 in the rack, you will need to open the unit to make sure the motherboard is properly installed and all the connections have been made.

1.Accessing the inside of the 6012P-6 (see Figure 2-5):

First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.

2.Check the CPUs (processors):

You should have one or two processors already installed into the system board. Each processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation.

3.Verify the proper CPU clock ratio setting:

If the CPU speed is not automatically detected you will need to set the correct speed with the BIOS Setup utility. See the CPU Speed and Fre- quency Ratio settings in BIOS (Chapter 7) for setting the proper CPU speed.

4.Check the system memory:

Your 6012P-6 server system may have come with system memory al- ready installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.

5.Installing add-on cards:

If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.

2-7

Page 25
Image 25
SUPER MICRO Computer 6012P-6 user manual Checking the Motherboard Setup