SUPERSERVER 6012P-6 User’s Manual

LAN1 Enable/Disable

Change the setting of jumper JP3 to enable or disable the onboard LAN1 or NIC (Network Interface Card) on the motherboard. See the table on the right for jumper settings. The default setting is enabled

LAN2 Enable/Disable

Change the setting of jumper JP27 to enable or disable the onboard LAN2 or NIC (Network Interface Card) on the motherboard. See the table on the right for jumper settings. The default setting is enabled.

VGA Enable/Disable

JP4 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings.

Chassis/Overheat Fan

Select

JP33 allows you to select to use ei- ther the CPU fan or the Chassis fan. The default position is open to select the CPU fan. The CPU Chas- sis fan is intended for use with Supermicro chassis. See the table on the right for jumper settings.

LAN1 (NIC)

Enable/Disable

Jumper Settings

(JP3)

Jumper

 

Position

Definition

Pins 1-2

Enabled

Pins 2-3

Disabled

 

 

LAN2 (NIC)

Enable/Disable

Jumper Settings

(JP27)

Jumper

 

Position

Definition

Pins 1-2

Enabled

Pins 2-3

Disabled

 

 

VGA Enable/Disable

Jumper Settings

(JP4)

Jumper

 

Position

Definition

1-2

Enabled

2-3

Disabled

 

 

CPU Chassis/CPU Fan

Select Jumper Settings

(JP33)

Jumper

 

Position

Definition

Open

CPU

Closed

CPU Chassis

 

 

5-18