Table 4-11. Hardware Health Monitor Submenu

 

 

 

Menu Item

 

Description

 

 

Use the "+" and "-" keys to set the CPU temperature threshold to between 65o

CPU Overheat

 

and 90o C. When this threshold is exceeded, the overheat LED on the chassis

 

will light up and an alarm will sound. The LED and alarm will turn off once the

Alarm

 

 

CPU temperature has dropped to 5 degrees below the threshold set. The default

 

 

 

 

setting is 72o C.

System Fan Monitor Submenu

 

 

This feature allows you to determine how the system will control the speed of the

Fan Speed

 

onboard fans. Select WORKSTATION if your system is used as a Workstation.

 

Select SERVER if your system is used as a server. Select Disable to disable the

Control

 

fan speed control function to allow the onboard fans to continuously run at full

 

 

speed (12V). The options are 1) Disable (Full Speed) 2) 3-PIN(SERVER) and 3)

 

 

3-PIN (WORKSTATION).

FAN1 Speed

 

The speeds of the onboard fans (in rpm) are displayed here.

through FAN4

 

Reading

 

 

 

 

Other items in the submenu are systems monitor displays for the following

Other

 

information:

 

CPU1 TEMPERATURE, CPU2 TEMPERATURE (for 2U systems), SYSTEM

Information

 

TEMPERATURE, VCOREA, VCOREB (for 2U systems), HT VOLTAGE, CPU1 MEM

 

 

VTT, CPU2 MEM VTT, CPU1 MEM, CPU2 MEM, 12V, 3.3V, VDD, 5V VSB,

 

 

MCP55VCORE, 1.5V and VBAT.

 

 

 

 

Table 4-12. IPMI Configuration

 

 

Menu Item

Description

View BMC System

Use the "+" and "-" keys to navigate through the system event log. Pressing the

Event Log

Enter key will open the following setting:

 

 

Clear BMC

Selecting this and pressing the Enter key will clear the BMC system event log.

System Event Log

Set LAN

Use the "+" and "-" keys to choose the desired channel number.

Configuration

 

 

 

IP Address

Use the "+" and "-" keys to select the parameter. The IP address and current IP

address in the BMC are shown.

 

MAC Address

Use the "+" and "-" keys to select the parameter. The MAC address and current

MAC address in the BMC are shown.

 

 

 

Subnet Mask

Use the "+" and "-" keys to select the parameter. The subnet address and current

subnet address in the BMC are shown.

 

Set PEF Configuration Submenu

 

 

PEF Support

Use this setting to ENABLE or Disable PEF support. When enabled, the following

settings will appear:

 

BMC Watch Dog

This setting is used to set the Watch Dog function. The options are Disabled,

Timer Action

RESET SYSTEM, POWER DOWN and POWER CYCLE.

 

 