- attach termination adapter -

If the terminus of the last section is not within this distance, use the telescopic vent section SV4.5LA, as the last vent section. For wall thicknesses greater than that shown in Figure 31, refer to table 3 on page 16. This table lists the additional venting components needed (in addition to the termination and adapter) for a particular range of wall thicknesses.

When using long square (SV4.5HTSSL) horizontal termination -

Assemble the vent system to point where the terminus of the last section is within 0 in. (0

mm)to 9³⁄₄ in. (248 mm) inboard of the exterior surface to which the termination is to be attached, see Figure 32.

K. When using square (SV4.5HTS) or short square (SV4.5 HTSS) horizontal termination

*Firestop/Spacer (SV4.5HF) shown on the exterior side of the wall. It may also be installed on the interior side.

*Note - Firestop/Spacer integral

with round termination

(SV4.5HTR)

*Note - When using Secure Flex use Firestop/Spacer SF4.5HF

See Venting Figures for Use Restrictions on the Horizontal Round Termination (SV4.5HTR).

6 to 48 inch Vent Section, Telescopic vent section, Elbow or Appliance Collar

SV4.5 HTSS

Termination

Shown.

Square (SV4.5HTS) 10¹⁄₂" (267 mm)

 

 

 

7"

 

 

 

 

Adapter

5¹⁄₈"

(178)

 

 

 

 

 

SV4.5RCH

(130 mm)

 

 

 

12¹⁄₈"

Note: Centerline of Vent

 

 

 

(308 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Piping is NOT the Same as

 

 

 

the Centerline of the

 

 

Base of Appliance

Framed Opening.

 

 

3"

(76 mm)

1"

(25.4 mm)

See Figure 9 on page 7 for Min. Distance to Base of Appliance.

- attach termination adapter -

Attach the adapter (adapter - SV4.5RCH - pro- vided with the termination) to the vent section or telescoping vent section), elbow or appliance

Installing Square HorizontalTermination (SV4.5HTS) Short Square Horizontal

Figure 29 Termination (SV4.5HTSS) Round Horizontal Termination (SV4.5HTR)

collar as shown in Figure 29 in the same manner as any SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall - When using either of the square terminations, install SV4.5HF (Secure Vent), or SF4.5HF (Secure Flex) firestop/spacer over the opening at the exterior side of the framing, long side up, with the 3 inch spacer clearance at the top as shown in Figure 29 or 30, and nail into place. (The Firestop/Spacer may be installed over the opening at the interior side of the framing.) When using the round termination, a separate firestop/spacer is not required since this termi- nation has integral spacers which provide the same function as a separate firestop/spacer.

*Firestop/Spacer (SV4.5HF) shown on the exterior side of the wall. It may also be installed on the interior side.

Note: Centerline of Vent Piping is NOT the Same as the Centerline of the Framed Opening. Short Square (SV4.5HTSS)

See Figure 9 on page 7

for Min. Distance to Base of Appliance.

Base of Appliance

6 to 48 inch Vent Section, Elbow or Appliance Collar

*When using Secure Flex, use

Firestop/Spacer (SF4.5HF)

Figure 30

SV4.5 HTSSL

Termination

or Round (SV4.5HTR) 10¹⁄₂" (267 mm)

3"

(76 mm)

1"

(25.4 mm)

7"

5¹⁄₈" (178)

(130 mm)

12¹⁄₈"

(308 mm)

Installing Long Square HorizontalTermination (SV4.5HTSSL)

*Note - Firestop/Spacer (SV4.5HF) required, but not shown for clarity.

Interior Surface of Finished Wall

Maximum Extent of

Vent Run Sections

Relative to Exterior

Surface of Framing

Last Vent Section. Use

Telescopic Vent Section

(SV4.5LA), If Necessary

Adapter

SV4.5RCH

Siding

Connecting/Recessing Minimum wall thickness *6 in. (152 mm)

Termination (SV4.5HTSSL) Maximum wall thickness

10¹⁄₄ in. (260 mm)

Manual background Exterior Surface of Siding

Manual background Exterior Surface of Framing

6 in. to 10¹⁄₄ in.

(152 mm to 260 mm)

*Cut termination collar for wall thicknesses

less than 6 in. (152 mm).

SV4.5HTSS Short

Square Termination

Shown

*Cut termination collar

for wall thicknesses

less than 10³⁄₄ in. (273 mm).

Interior Surface of Finished Wall Manual background

Maximum Extent of

Vent Run Sections Relative to Exterior Surface of Framing Manual background

Last Vent Section

Termination Securing

Screw

Siding

Manual background Minimum wall thickness *10³⁄₄ in. (273 mm)

Manual background Maximum wall thickness 20 in. (508 mm)

Manual background Exterior Surface of Siding

Manual background Exterior Surface of Framing

Manual background 10³⁄₄ to 20 in. (273 to 508 mm)

SV4.5HTSSL Long

Square Termination

 

 

 

 

 

1¹⁄₄" Maximum Recess of Square

 

 

 

 

 

Termination into Exterior Finishing

 

 

 

 

 

Material. Round Termination may

 

 

 

 

 

not be recessed at all.

 

 

 

 

 

*When using Secure Flex, use

 

 

 

 

 

Firestop/Spacer SF4.5HF

 

 

 

 

 

Connecting/Recessing

 

 

 

 

 

Square (SV4.5HTS)

 

SV4.5HTSS Short Square

 

Short Square (SV4.5HTSS)

Stucco

Termination Shown

 

 

 

 

or Round (SV4.5HTR)

 

Figure 31

 

Horizontal Termination

 

SV4.5HTSSL Long

Stucco

Square Termination

 

Figure 32

1¹⁄₄" Maximum Recess of Square Termination into Exterior Finishing Material

*Note - Firestop/Spacer

(SV4.5HF) required, but not

shown for clarity.

*When using Secure Flex, use

Firestop/Spacer SF4.5HF.

Connecting/Recessing

Long Square Horizontal

Termination (SV4.5HTSSL)

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

15

Page 15
Image 15
Superior DT-400CEN attach termination adapter, Short Square SV4.5HTSS, or Round SV4.5HTR, Termination SV4.5HTSSL