GAS CONVERSION KITS
WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S IN- STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EX- ACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CON- VERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORM- ING THIS INSTALLATION ASSUMES RESPONSI- BILITY FOR THIS CONVERSION.
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDEDECARBONEPEUTRÉSULTERLEDOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.
In Canada:
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE
AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1- B149.1 ET.2.
Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the neces- sary components needed to complete the task including labeling that must be affixed to en- sure safe operation.
Kit part numbers are listed here and the follow- ing steps detail the conversion procedure.
Step 1. Turn off the gas supply to the appliance. Remove the front glass door/frame from the appliance. Access the control compartment.
Step 2. Carefully remove the logs. Exercise care as not to break the logs.
Step 3. Locate the screws securing the burner (tray) to the appliance. Remove the burner and retain the securing screws.
Natural To Propane Gas Conversion Kit
(SIT Systems)
Models No. | Unit Type | Catalog No. |
|
|
|
millivolt | H1594 | |
|
|
|
millivolt | H1594 | |
|
|
|
electronic | 99L90 | |
|
|
|
electronic | 99L90 | |
|
|
|
Propane to Natural Gas Conversion Kit
(SIT Systems)
Model No. | Unit Type | Catalog No. |
|
|
|
millivolt | H1595 | |
|
|
|
millivolt | H1595 | |
|
|
|
electronic | 99L91 | |
|
|
|
electronic | 99L91 | |
|
|
|
Step 4. Millivolt Appliances - SIT Systems
a. See Figure 59 and the instructions provided with the kit. Using a Torx T20, remove and discard the three pressure regulator mounting screws. Remove the pressure regulator, spring, poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gas- ket installed on the back of the replacement pressure regulator is properly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque.
Natural To Propane Gas Conversion Kit
(Honeywell Systems)
Models No. | Unit Type | Catalog No. |
|
|
|
millivolt | 26M51 | |
|
|
|
millivolt | 26M51 | |
|
|
|
electronic | 99L90 | |
|
|
|
electronic | 99L90 | |
|
|
|
Propane to Natural Gas Conversion Kit
(Honeywell Systems)
Model No. | Unit Type | Catalog No. |
millivolt | 26M55 | |
millivolt | 26M55 | |
electronic | 99L91 | |
electronic | 99L91 | |
SIT Millivolt Gas Valve | ||
Pressure |
|
|
Regulator |
|
|
| Remove | |
| These | |
| Components | |
Figure 59 |
|
|
26