Superior DR-400CEP Horizontal Vent Figures/Table Continued, Table J, H + H1 Maximum termination

Models: DR-400CMN DR-400CEP DT-400CMN DT-400CMP DR-400CEN DT-400CEN DT-400CEP DR-400CMP

1 28
Download 28 pages 33.19 Kb
Page 18
Image 18
HORIZONTAL VENT FIGURES/TABLE (CONTINUED)

HORIZONTAL VENT FIGURES/TABLE (CONTINUED)

 

TABLE J

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior

 

wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR)

 

 

 

V MINIMUM

H + H1 Maximum termination .

 

*Wall Firestop/Spacer

feet

(m)

feet

(m)

 

(SV4.5HF)

1

(0.305)

5

(1.52)

 

H

2

(0.610)

10

(3.1)

 

 

3

(0.914)

15

(4.65)

H1

V

4

(1.22)

20

(6.2)

 

 

V + H+ H1 = 40 feet (12.4 m) Max.

 

 

H + H1= 20 feet (6.2 m) Max.

*When using Secure Flex,

*Wall Firestop/Spacer

Short Square Termination (SV4.5HTSS) shown;

use Wall Firestop/Spacer

(SV4.5HF)

SF4.5HF.

 

Long Square Termination (SV4.5HTSSL) may also be used;

**When using Secure

**Ceiling

Square Termination (SV4.5HTS) may also be used

Flex, use Ceiling

Firestop/Spacer

Round Termination (SV4.5HTR) may also be used.

Firestop/Spacer

(SV4.5BF)

Figure 39- Top Vent - TWO 90 DEGREE ELBOWS

SF4.5BF.

 

 

 

 

 

TABLE K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V Minimum

H Maximum

H+H1+H2

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

feet

(m)

feet

(m)

feet

 

(m)

 

 

 

 

 

 

 

 

 

 

 

H2

 

1

(0.305)

2

(0.610)

5

 

(1.52)

 

 

2

(0.610)

4

(1.22)

10

 

(3.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

3

(0.914)

6

(1.86)

15

 

(4.65)

*When using Secure Flex,

 

 

 

 

 

 

 

use Wall Firestop/Spacer

4

(1.22)

8

(2.48)

20

 

(6.2)

 

SF4.5HF.

 

 

 

 

 

 

 

 

 

 

 

V+H+H1+H2 = 40 feet (12.4 m) Max.

 

**When using Secure Flex,

 

H = 8 feet (2.48 m) Max.

 

use Ceiling Firestop/Spacer

 

H+H1+H2= 20 feet (6.2 m) Max.

 

SF4.5BF.

 

 

 

 

 

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used;

Square Termination (SV4.5HTS) may also be used

Round Termination (SV4.5HTR) may also be used.

Figure 40 - Rear Vent - THREE 90 DEGREE ELBOWS

*Wall Firestop/Spacer

(SV4.5HF)

H1

**Ceiling Firestop/Spacer

(SV4.5BF)

V

TABLE JH

 

TABLE L

 

 

 

V MINIMUM

H Maximum

H1

 

feet

(m)

feet

(m)

 

 

 

1

(0.305)

5

(1.52)

 

 

2

(0.610)

10

(3.1)

 

 

3

(0.914)

15

(4.65)

 

 

4

(1.22)

20

(6.2)

 

 

H +H1= 20 feet (6.2 m) Max.

*Wall Firestop/spacer

V1

V+V1+H+H1 = 40 feet (12.4 m) Max.

(SV4.5HF)

 

 

 

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used;

Square Termination (SV4.5HTS) may also be used

Round Termination (SV4.5HTR) may also be used.

Figure 41 - Top Vent - THREE 90 DEGREE ELBOWS

*When using Secure Flex, use Wall Firestop/spacer SF4.5HF.

**When using Secure flex, use Ceiling Firestop/spacer SF4.5BF.

**Ceiling Firestop/spacer H + H1 Maximum termination . (SV4.5BF)

H

V

*Wall Firestop/spacer

(SV4.5HF)

18

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.