TABLE F

HORIZONTAL VENT FIGURES/TABLES (CONTINUED)

TABLE F

 

V = 0ne 90 degree elbow

H

H = 3 feet (0.914 m) Max.

 

V

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

*Wall Firestop/Spacer

(SV4.5HF)

*When using Secure Flex, use Wall Firestop/Spacer SV4.5HF.

Figure 36 - Top Vent - ONE 90 DEGREE ELBOW - ELBOW CONNECTION AT APPLIANCE

TABLE G

V Minimum

H Maximum

feet

(m)

feet

(m)

1

(0.305)

5

(1.52)

2

(0.61)

10

(3.1)

3

(0.914)

15

(4.65)

4

(1.22)

20

(6.2)

V + H = 40 feet (12.4 m) Max.

H = 20 feet (6.2 m) Max.

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

TABLE H

V Minimum

H Maximum

H+H1 Maximum

feet

(m)

feet

(m)

feet

(m)

 

 

 

 

 

 

1

(0.305)

2

(0.610)

5

(1.52)

 

 

 

 

 

 

2

(0.610)

4

(1.22)

10

(3.1)

 

 

 

 

 

 

3

(0.914)

6

(1.86)

15

(4.65)

 

 

 

 

 

 

4

(1.22)

8

(2.48)

20

(6.2)

 

 

 

 

 

 

V+H+H1 = 40 feet (12.4 m) Max.

H = 8 feet (2.48 m) Max.

H + H1 = 20 feet (6.2 m) Max.

Refer to Table 3 on page 16 for an aid in venting component selection for a particularrangeofexteriorwallthicknesseswhenusingthesquare(SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

*When using Secure Flex, use Wall Firestop/Spacer

SF4.5HF.

H

H1

H

*Wall

V

*Wall Firestop/Spacer

(SV4.5HF)

**Ceiling Firestop/Spacer

(SV4.5BF)

**When using Secure Flex, use Ceiling

Firestop/Spacer SF4.5BF.

Figure 37 - Top Vent - ONE 90 DEGREE ELBOW -

ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

Firestop/Spacer

(SV4.5HF)

**Ceiling

H+H1 Maximum Firestop/Spacer

(SV4.5BF)

*When using Secure

 

*Wall

Flex, use Wall

 

Firestop/Spacer

V

Firestop/Spacer

SF4.5HF.

 

(SV4.5HF)

**When using Secure

Flex, use Ceiling Firestop/Spacer SF4.5BF.

Figure 38- Rear Vent - TWO 90 DEGREE ELBOWS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.