TANDBERG D13202 manual Hardware And Cabling, Tandberg Gw, DCE, 9 pin, DTE, 9 pin

Models: D13202

1 32
Download 32 pages 14.21 Kb
Page 4
Image 4
2.1.Hardware And Cabling

TANDBERG GW

Dataport Command Interface User Guide

2.Connecting to the Dataport Command Interface through the RS-232 port.

The RS-232 port is a 9-pin, female, D-sub connector located on the back of the GW. The port is configured as a DCE (Data Communications Equipment). The RS-232 port is default set to 9600 baud, 8 databits, none parity and 1 stopbit from factory. The RS-232 port is also referred to as the Dataport.

2.1.Hardware And Cabling

The pin outs for the RS-232 are defined in the following table (the DTE, Data Terminal Equipment, could be a PC or other device capable of serial communication).

Pin no

Signal

Description

Direction

1

CD

Carrier detect

To DTE

2

RD

Receive data

To DTE

3

TD

Transmit data

From DTE

4

DTR

Data terminal ready

From DTE

5

 

Ground

 

6

DSR

Data set ready

To DTE

7

RTS

Ready to send

From DTE

8

CTS

Clear to send

To DTE

9

RI

Ring indicator

To DTE

NOTE! A straight through cable should be used between the TANDBERG GW’s RS-232 port and the DTE.

The figure below illustrates the recommended cable-wiring scheme for connecting the GW to a PC through RS-232.

TANDBERG GW

PC

 

 

DCE, 9 pin

DTE, 9 pin

 

1

CD

1

CD

2

RD

2

RD

3

TD

3

TD

4

DTR

4

DTR

5

GND

5

GND

6

DSR

6

DSR

7

RTS

7

RTS

8

CTS

8

CTS

9

RI

9

RI

 

 

 

 

DTR and RTS are ignored. DSR, CD, and CTS are always asserted, while RI is not used.