Health Care System III

General Use

Voice Activated Camera Positioning

Through Voice Activated Camera Positioning and the use of two or three microphones, the camera will automatically view the speaker.

Setup

Before using camera tracking, the camera positions used must be stored at presets P7 (Mic1), P8 (Mic2) and/ or P9 (Mic3).

EXAMPLE:

THE CAMERA POSITION STORED AT P7 MUST BE RELATED TO MIC1, THEREFORE ALL PARTICIPANTS WHO ARE LOCATED CLOSEST TO MIC1

SHOULD BE INCLUDED IN THE P7 CAMERA POSITION ETC. WHEN CAMERA TRACKING IS ACTIVATED AND A PERSON CLOSE TO MIC1 SPEAKS,

P7 WILL BE AUTOMATICALLY SELECTED.

Activating

presets Enable Camera Tracking by pressing ‘CamTrack On’ in the ‘Preset 0-9 menu, which is

Pactivated by pressing the P button on the remote control. An on-screen indicator ‘CamTrackOn’ will appear.

mic off

When activating another video source (e.g., document camera), camera tracking will be

temporarily disabled until you re-select MainCam or a MainCam preset.

 

Pressing MIC OFF will temporarily disable camera tracking.

A Voice Detector makes the system more tolerent of noise and ensures the camera will not be moved by noise such as paper shuffling, etc.

Deactivating

Disable Camera Tracking by:

moving the camera manually.

activating a MainCam preset when MainCam is already activated.

disconnecting the call.

An on-screen indicator ‘CamTrackOff’ will appear.

TIP

THE CAMERA TRACKING SPEEDS MAY BE ALTERED IN THE ‘VIDEO SETTINGSMENU. SEE ‘ADVANCED USEFOR

FURTHER DETAILS.

43

Page 43
Image 43
TANDBERG D50104-15 user manual Voice Activated Camera Positioning, Setup, Activating, Deactivating