Adjust the audio input levels according to which external audio equipment is connected. The
The default levels for Mic 1,2 and 3 are set for use with an Audio Technica AT871 microphone in an average videoconferencing room. The gain can be adjusted correctly for a wide range of microphones.
A few examples of microphone levels are:
Audio Technica AT871 | +3dB (default with system) |
Audio Technica AT851R | +7dB |
TANDBERG Audio Science | +19.5dB |
Audio 4, 5 and 6 are set to a default level which is adhered to by most manufacturers of
Audio Outputs
Audio out 1 is intended for connection to TANDBERG Natural Audio, televisions or audio amplifiers.
Audio out 2 is intended for connection to audio recording equipment or to a telephone
Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix of audio from far end and local end (not from Audio in 6).
Audio Module: Select Natural Audio Module according to the type of Audio Module installed.
NOTE
NEVER CONNECT AUDIO OUT 2 OR AUDIO OUT 3 TO A LOUDSPEAKER PLACED IN THE SAME ROOM AS THE MICROPHONES CONNECTED TO THE
SYSTEM. DOING THIS WILL CAUSE “HOWLING” AND POSSIBLE DAMAGE TO THE SPEAKER SYSTEM.
If an output is ‘Off’, no audio will be sent to that output.