22 Section 2
The Nx12 fully supports Livewire. For more information on using the Nx12 with a Livewire
IMPORTANT
If you are not using a
The
♦♦ The green Link LED indicates the presence of a live physical connection to a working Ethernet hub (or other device). If the green indicator does not light you should check your network wiring. Absence of the link light could also indicate a hardware failure of the Nx12.
♦♦ The amber Activity LED indicates network activity on this segment of the network. Depending on network activity, this indicator may only illuminate occasionally; flickering of this light is normal.
For details on using
For information on using Telos Assistant Producer and other call screening applications, see Section 5.10.
2.10 Parallel GPIO Remote Control
This port provides inputs to and outputs from the Nx12. Inputs can be connected to logic outputs or switch closures. Outputs can be connected to external device logic inputs.
When any of the
The available functions are:
Record Control Outputs (See Section 4.3)
Ring Mute In – This input will mute the ringers on all of the Desktop Directors connected to this Nx12.
User Out (Delay Dump) – This output will be active (low) when the User button is pressed. It will remain asserted until that button is released.
Ringing Out – This output is active (low) whenever the system has one or more lines in the ringing state.
Priority Ringing Out – Active (low) when a line designated as a Priority Line is ringing.
Nx12 GPIO D-Connector
PIN DESCRIPTION
1Ground
2User Out (Dump) 1
3Ringing Out 1
4Priority Ringing Out 1