Content of PRGS430.ini File
2-9
Operation
2.2.4 Content of PRGS430.ini File
The last settings of the PRGS430 graphical user interface (GUI) are stored in
the .ini file before exiting the program. This information is stored under the
Program Device System section.
Additionally, the following parameters are in the [Options] section and may be
modified:
[Options]
\BlowFuse = 1 The blow fuse button in the GUI is disabled to prevent
accidental blow of the irreversible fuse.
LastResult = 0 If the program is called with command-line parameter, the
error code which is returned to the system when exiting the program is also
stored here.
2.2.5 Use of a [Project].ini File
Some default options could be changed within a [Project].ini file. This file has
to be in the same directory as the object code file. The following variables could
be defined or redefined there.
The name of the file should have the same name as the object file with the
extension .ini.
[ProgramDevice]
UserMemProtect = Start, Size
UserMemProtect2 = Start, Size
UserMemProtect3 = Start, Size
UserMemProtectn = Start, Size
DisableTIMemProtect = 0
Memory ranges defined in the UserMemProtect and UserMemProtect [n]
option are read out and reprogrammed after erase (flash device only). [n] could
be a number 2 and be in ascending order.
If a memory protection is activated in the device definition file from Texas
Instruments, it could be switched off with the DisableTIMemProtect = 1 option.