SVS Operation

6-6 Supply Voltage Supervisor

6.2.4 SVS Operating Range

Each SVS level has hysteresis to reduce sensitivity to small supply voltage

changes when AVCC is close to the threshold. The SVS operation and

SVS/Brownout interoperation are shown in Figure 63.

Figure 63. Operating Levels for SVS and Brownout/Reset Circuit
V
CC(start)
AV
CC
V
(B_IT)
Brownout
Region
V
(SVSstart)
V
(SVS_IT)
td(SVSR)
undefined
Vhys(SVS_IT)
0
1
td(BOR)
Brownout
0
1
td(SVSon)
td(BOR)
0
1
Set POR
Brown-
Out
Region
SVS Circuit Active
SVSOUT
Vhys(B_IT)
Software Sets VLD>0