LCD_A Controller Operation
19-26 LCD_A Controller
LCDAVCTL1, LCD_A Voltage Control Register 1
76543210
Unused VLCDx Unused
rw0 rw0 rw0 rw0 rw0 rw0 rw0 rw0
Unused Bits
75Unused
VLCDx Bits
41Charge pump voltage select. LCDCPEN must be 1 for the charge pump to
be enabled. AVCC is used for VLCD when VLCDx = 0000 and VREFx = 00
and VLCDEXT = 0.
0000 Charge pump disabled.
0001 VLCD = 2.60V
0010 VLCD = 2.66V
0011 VLCD = 2.72V
0100 VLCD = 2.78V
0101 VLCD = 2.84V
0110 VLCD = 2.90V
0111 VLCD = 2.96V
1000 VLCD = 3.02V
1001 VLCD = 3.08V
1010 VLCD = 3.14V
1011 VLCD = 3.20V
1100 VLCD = 3.26V
1101 VLCD = 3.32V
1110 VLCD = 3.38V
1111 VLCD = 3.44V
Unused Bit 0 Unused