LCD_A Controller Operation
19-25LCD_A Controller
LCDAVCTL0, LCD_A Voltage Control Register 0
76543210
Unused R03EXT REXT VLCDEXT LCDCPEN VLCDREFx LCD2B
rw0 rw0 rw0 rw0 rw0 rw0 rw0 rw0
Unused Bit 7 Unused
R03EXT Bit 6 V5 voltage select. This bit selects the external connection for the lowest
LCD voltage. R03EXT is ignored if there is no R03 pin available.
0 V5 is AVCC
1 V5 is sourced from the R03 pin
REXT Bit 5 V2 V4 voltage select. This bit selects the external connections for
voltages V2 V4.
0 V2 V4 are generated internally
1 V2 V4 are sourced externally and the internal bias generator is
switched off
VLCDEXT Bit 4 VLCD source select
0V
LCD is generated internally
1V
LCD is sourced externally
LCDCPEN Bit 3 Charge pump enable.
0 Charge pump disabled.
1 Charge pump enabled when VLCDx > 0 or VLCDREFx > 0 and
VLCDEXT = 0
VLCDREFx Bits
21Charge pump reference select
00 Internal
01 External
10 Reserved
11 Reserved
LCD2B Bit 0 Bias select. LCD2B is ignored when LCDMx = 00.
0 1/3 bias
1 1/2 bias