USART Registers: SPI Mode

15-17USART Peripheral Interface, SPI Mode

UxBR0, USART Baud Rate Control Register 0
76543210
2726252423222120
rw rw rw rw rw rw rw rw
UxBR1, USART Baud Rate Control Register 1
76543210
215 214 213 212 211 210 2928
rw rw rw rw rw rw rw rw

UxBRx The baud-rate generator uses the content of {UxBR1+UxBR0} to set the

baud rate. Unpredictable SPI operation occurs if UxBR < 2.

UxMCTL, USART Modulation Control Register
76543210
m7 m6 m5 m4 m3 m2 m1 m0
rw rw rw rw rw rw rw rw

UxMCTLx Bits

70The modulation control register is not used for SPI mode and should be set

to 000h.